Doepfer A-190-1 MIDI-CV/Gate/Sync Interface Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Audio Doepfer A-190-1 MIDI-CV/Gate/Sync Interface herunter. Doepfer A-190-1 MIDI-CV/Gate/Sync Interface User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
doepfer
System A - 100
MIDI-CV/SYNC Interface A-190
1
1. Introduction
The A-190 is a MIDI-CV/SYNC Interface, with which
you can control any A-100 Module which has CV and
gate/trigger input sockets by MIDI.
The A-190 has two Digital-to-Analogue converters
(DAC for short), which put out control voltages from 0
V to +5 V, so that you can control not just the pitch, but
also another voltage-controllable parameter on the
A-100.
DAC 1
is ‘hard-wired’ to receive MIDI
note messages
and convert them into control voltages available at CV
output socket CV 1. The DAC has 12-bit resolution,
which gives excellent tuning resolution (in steps of
1/4096th). As a rule, DAC 1 will be used to control
VCO pitch
.
DAC 2 can be assigned to your choice of MIDI con-
troller
. This DAC has 7-bit resolution (1/128th steps).
Its output is available at CV 2, and can be used for
voltage control of any suitable module (eg VCF, VCA,
etc.).
The A-190 also has a clock output, controlled by MIDI
clock. This can be divided down to provide a variety of
clock outputs, and enable older sequencers or drum
machines to be synced to MIDI.
A Reset Output provides control of the A-160 / 161
Clock Divider / Sequencer or can produce MIDI-
synchronised gates (for instance on an ADSR). MIDI
START or CONTINUE messages make the voltage at
the Reset output go low, and MIDI STOP messages
make it go high.
In addition, the A-190 allows for portamento (glide)
and pitch-bend, and provides a software LFO. These
functions can all be switched on and off or altered by
MIDI controllers.
All control parameters can be saved in non-volatile
memory
.
H The A-190 needs an additional power supply
(+5 V / 50 mA) for connection to the system
bus.
To install the A-190 please look at the
important information on p. 4!
A
Seitenansicht 0
1 2 3 4 5 6 ... 21 22

Inhaltsverzeichnis

Seite 1 - 1. Introduction

doepferSystem A - 100MIDI-CV/SYNC Interface A-19011. IntroductionThe A-190 is a MIDI-CV/SYNC Interface, with whichyou can control any A-100 Module

Seite 2 - A-190

A-190 MIDI-CV/SYNC InterfaceSystem A - 100doepfer10CLOCK TIMEThis parameter sets the amount by which the MIDIclock is divided before being sent to t

Seite 3

doepferSystem A - 100MIDI-CV/SYNC Interface A-19011REF. OFFSETThis parameter sets the voltage offset for the bottomnote - and works in the same way

Seite 4 - 3. Starting to use the A-190

A-190 MIDI-CV/SYNC InterfaceSystem A - 100doepfer12RTRIG. TIMEThis parameter sets the gate retrigger time - ie. thetime that elapses before another

Seite 5 - 4.1 Using the A-190

doepferSystem A - 100MIDI-CV/SYNC Interface A-19013ASSIGN CV2This parameter sets which MIDI message is sent toDAC 2, and thus to the CV2 output sock

Seite 6

A-190 MIDI-CV/SYNC interfaceSystem A - 100doepfer144.3 PERFORMANCE MenusCHANNELThe CHANNEL parameter sets the MIDI receivechannel. MIDI messages re

Seite 7

doepferSystem A - 100MIDI-CV/SYNC interface A-19015GLIDE TIMEThe Glide Time parameter controls the length of theportamento time in the A-190’s built

Seite 8 - GATE POLARITY

A-190 MIDI-CV/SYNC interfaceSystem A - 100doepfer16No function at presentReserved for future expansion (e.g. arpeggiator)BEND WIDTHThe BEND WIDTH pa

Seite 9 - RETRIGGER

doepferSystem A - 100MIDI-CV/SYNC interface A-190174.4 Storing set-upsThe A-190 is equipped with a non-volatile memory(EEPROM - electrically erasea

Seite 10 - CLOCK POLARITY

A-190 MIDI-CV/SYNC interfaceSystem A - 100doepfer184.5 PERFORMANCE modeIn performance mode the A-190 converts incomingMIDI messages into CV and ga

Seite 11 - SCALE parameter is

doepferSystem A - 100MIDI-CV/SYNC interface A-19019CONTROLLER #68 (Legato)The retrigger function (see CONFIG menu 1) canalso be switched on and off

Seite 12 - RTRIG. TIME

A-190 MIDI-CV/SYNC InterfaceSystem A - 100doepfer22. OverviewControls and indicators1 Group : Button to select which menu section(out of the Confi

Seite 13 - MIDI-CV/SYNC Interface A-190

A-190 MIDI-CV/SYNC interfaceSystem A - 100doepfer204.6 Initialisation (Reset)When the A-190 is first switched on after leaving thefactory, its memo

Seite 14 - Performance Menu 1

doepferSystem A - 100MIDI-CV/SYNC interface A-19021Parameter Value NotesCHANNEL 0 MIDI channel 1REF. NOTE 36 C3CLOCK TIME 1 clock frequency at outpu

Seite 15 - ASSIGN MODE

A-190 MIDI-CV/SYNC interfaceSystem A - 100doepfer22Controller Effect SettingCont 01 nModulationn = LFO voltage amount sent to CV 1Cont 05 nGlid

Seite 16 - Performance Menu 6

doepferSystem A - 100MIDI-CV/SYNC Interface A-1903In / Outputs! MIDI THRU : Output for relaying MIDI messagessent to MIDI IN to another MIDI unit.&

Seite 17 - 4.4 Storing set-ups

A-190 MIDI-CV/SYNC InterfaceSystem A - 100doepfer43. Starting to use the A-190Before switching your system on, use a MIDI cable toconnect between y

Seite 18 - CONTROLLER #65 (Portamento)

doepferSystem A - 100MIDI-CV/SYNC Interface A-19054.1 Using the A-190On power up, the A-190 defaults to Performancemode. This is the normal mode of

Seite 19 - CONTROLLER #92 (Tremolo)

A-190 MIDI-CV/SYNC InterfaceSystem A - 100doepfer6Pressing the Group button 1 switches to the othermenu group - the button acts as a toggle switch.

Seite 20 - 4.6 Initialisation (Reset)

doepferSystem A - 100MIDI-CV/SYNC Interface A-1907Changing parametersThere are two ways of changing parameters on theA-190: either manually, or by s

Seite 21

A-190 MIDI-CV/SYNC InterfaceSystem A - 100doepfer84.2 CONFIG menusCHANNEL / REF. NOTEThe CHANNEL parameter sets the MIDI receivechannel. In perf

Seite 22

doepferSystem A - 100MIDI-CV/SYNC Interface A-1909CV CHAR.This parameter sets the voltage control characteri-stics of the pitch CV output from the

Kommentare zu diesen Handbüchern

Keine Kommentare